MEQUON, Wis.--(BUSINESS WIRE)--Titan Spine, a medical device surface technology company focused on developing innovative spinal interbody fusion implants, today announced that it has received 510(k) clearance from the U.S. Food and Drug Administration (FDA) to market its Endoskeleton® line of interbody fusion implants featuring its next-generation nanoLOCKTM surface technology. This clearance marks Titan’s line of Endoskeleton® spinal implants as the first FDA-approved interbody fusion devices to feature nanotechnology.
The nanoLOCKTM technology will be highlighted at the 2014 North American Spine Society (NASS) Annual Meeting, being held November 12-15, 2014 in San Francisco, Calif., at the Titan Spine booth #1923.
Titan’s new nanoLOCKTM surface technology enhances the Company’s line of Endoskeleton® devices with an increased amount of nano-scaled textures to up-regulate a statistically significant greater amount of the osteogenic and angiogenic growth factors that are critical for bone growth and fusion when compared to PEEK1 and the company’s current surface.2
Barbara Boyan, Ph.D., Dean of the School of Engineering at Virginia Commonwealth University and an investigator in various Titan Spine studies, said, “This new surface technology further enhances Titan’s current surface and is the result of extensive research in how to create a significantly greater amount of nano-scaled textures that we have shown to be important for the osteogenic response necessary for fusion. The nanoLOCKTM surface topography is far different than what is found on titanium-coated PEEK implants. In addition, the nanoLOCKTM surface is not created by applying a coating, but rather is formed by a reductive process of the titanium itself. This eliminates the potential for delamination, which is a concern for products with a PEEK-titanium interface. My team is proud to collaborate with Titan Spine to help develop such a differentiated technology that is truly designed to benefit both patients and surgeons.”
Titan’s nanoLOCKTM surface is a significant advancement of the company’s first-generation surface. The patented nanoLOCKTM manufacturing process creates additional textures at the critical nano level. However, there are no changes to the device indications for use, design, dimensions, or materials. Additionally, mechanical testing demonstrated that the strength of the company’s line of Endoskeleton® implants are unaffected by the new surface treatment.
Paul Slosar, M.D., Chief Medical Officer for Titan Spine, commented, “Our new surface technology represents a significant technological breakthrough in treating patients that require interbody fusion. What we have learned is that there are very specific implant surface topographies, especially at the nano level, that generate the osteogenic and angiogenic responses necessary to drive bone growth required for a robust fusion. The nanoLOCKTM surface is the result of this extensive research and represents the new standard in spinal fusion interbody implants. Titan Spine will offer its complete line of titanium devices for interbody fusion spine surgery procedures in the cervical and lumbar spine now with nano-scale features that offer added benefits to patients.”
Peter Ullrich, MD, former spine surgeon and Chief Executive Officer of Titan Spine, remarked, “Receiving FDA approval for our next-generation surface technology is a tremendous milestone for Titan Spine. This marks the first clearance of nanotechnology interbody devices by the FDA, which is an acknowledgement to Titan’s leadership in developing nanotechnology for the spine and potentially other orthopedic applications. We will continue to innovate the spinal interbody market through close collaboration with leading academic pioneers in material science and biomedical engineering and look forward to future enhancements to our Endoskeleton® devices."
The full line of Endoskeleton® devices will feature Titan Spine’s proprietary nanoLOCKTM implant surface technology, consisting of a unique combination of roughened topographies at the macro, micro, and nano levels. This unique combination of surface topographies is designed to create an optimal host-bone response and actively participate in the fusion process by promoting new bone growth, encouraging natural production of bone morphogenetic proteins (BMPs)2 and creating the potential for a faster and more robust fusion.
About Titan Spine
Titan Spine, LLC is a surface technology company focused on the design and manufacture of interbody fusion devices for the spine. The company is committed to advancing the science of surface engineering to enhance the treatment of various pathologies of the spine that require fusion. Titan Spine, located in Mequon, Wisconsin and Laichingen, Germany, markets a full line of Endoskeleton® interbody devices featuring its proprietary textured surface in the U.S. and portions of Europe through its sales force and a network of independent distributors. To learn more, visit www.titanspine.com.
1 Olivares-Navarrete, R., Hyzy, S.L., Slosar, P.J., Schneider, J.M., Schwartz, Z., & Boyan, B. D. Implant Materials Generate Different Peri-Implant Inflammatory Factors: PEEK Promotes Fibrosis and Micro-textured Titanium Promotes Osteogenic Factors. 21st International Meeting on Advanced Spine Techniques; 2014; Jul 16-19; Valencia, Spain.
2 Olivares-Navarrete, R., Hyzy, S. L., Berg, M. E., Schneider, J. M., Hotchkiss, K., Schwartz, Z., & Boyan, B. D. Osteoblast Lineage Cells Can Discriminate Microscale Topographic Features on Titanium–Aluminum–Vanadium Surfaces. Ann Biomed Eng. 2014; 1-11.